top of page

2.3 More microscopy

OCR A-level Biology Year 1 (AS-level) · OCR H420/H020 · Chapter 2: Basic components of living systems

A free OCR A-level Biology Year 1 lesson for OCR A level Biology A (H420) and AS Biology A (H020) from OBA School: electron microscopes, laser scanning confocal microscopy, and the difference between magnification and resolution. Watch the video, read the explanation, then try the revision questions. You can work through the full lesson, with more videos, interactive activities, a practice quiz and printable worksheets, in our free online course.

What you will learn

  • Explain the difference between magnification and resolution
  • Describe how a transmission and a scanning electron microscope produce images
  • Compare light microscopes, TEMs and SEMs for resolution, magnification and the specimens they can use
  • Outline how laser scanning confocal microscopy works and why it is useful
  • Recognise artefacts and explain why they occur

Key words

  • Resolution: The shortest distance between two objects that can still be seen as separate. Smaller value = better resolution.
  • TEM: Transmission electron microscope: electrons pass through an ultra-thin section to give a 2D image of internal structure.
  • SEM: Scanning electron microscope: electrons are scattered from the coated surface of a specimen to give a 3D image.
  • Laser scanning confocal microscope: A light microscope that scans a fluorescent specimen with a laser, point by point, to build sharp images at chosen depths.
  • Artefact: A feature in an image produced by the preparation method rather than present in the living cell.

Magnification is not resolution

Magnification tells you how much bigger the image is. Resolution (resolving power) tells you how much detail you can see: the smallest separation at which two points still look like two. Enlarging an image beyond the resolution limit just enlarges the blur.

Resolution is limited by the wavelength of the radiation used. Visible light has a wavelength of about 400 to 700 nm, so the best light microscopes resolve about 200 nm. Electron beams have a much shorter wavelength, so electron microscopes resolve down to well under 1 nm.

  • Radiation; Light Visible light; TEM Electrons; SEM Electrons
  • Approximate resolution; Light 200 nm; TEM 0.1 to 0.5 nm; SEM about 3 to 10 nm
  • Useful magnification; Light up to about ×1500; TEM up to about ×1 000 000; SEM up to about ×500 000
  • Image; Light 2D, colour; TEM 2D, black and white; SEM 3D surface, black and white
  • Living specimens?; Light Yes; TEM No (vacuum); SEM No (vacuum)

Exam tip: OCR do not expect you to recall exact figures; you must know the order: TEM gives the best resolution, then SEM, then the light microscope.

Electron microscopes

In a TEM, the specimen is fixed, stained with heavy metal salts (such as lead or osmium) and cut into sections about 50 to 100 nm thick. Denser parts absorb or scatter more electrons and look darker. TEMs reveal the internal ultrastructure of cells, such as the cristae of mitochondria and the thylakoids in chloroplasts.

In an SEM, a whole specimen is coated in a thin layer of metal such as gold. The beam is scanned across the surface and the scattered electrons are detected to build a 3D image, for example of the surface of a pollen grain or a red blood cell.

  • Much higher resolution, so organelles and membranes can be studied; Disadvantages Specimens must be dead and in a vacuum
  • Higher useful magnification; Disadvantages Complex preparation can produce artefacts
  • SEM shows 3D surface structure; Disadvantages Very expensive, large, need training; images are black and white (colour is added digitally)

Laser scanning confocal microscopy

The specimen is stained with fluorescent dyes. A laser beam is focused on one tiny point at a time and the fluorescent light emitted passes back through a pinhole. Light from above and below the focal plane is blocked by the pinhole, so the image is sharp. The laser scans across the specimen point by point and the computer builds an image.

  • Images can be made at different depths (optical sectioning) and combined into a 3D image.
  • Living cells can be studied, and the movement of fluorescent-tagged molecules can be followed.
  • Used in research and medicine, for example to look at cells deep in thick tissue or to find fungal infections in the cornea.

Worked example: choosing a microscope

A scientist wants to watch a fluorescent-tagged protein move to the cell surface membrane of living cells.
TEM and SEM need dead specimens in a vacuum, so they are ruled out.
A confocal microscope can image fluorescence in living cells at a chosen depth.

Answer: Laser scanning confocal microscope

Newer techniques

  • Atomic force microscope: a tiny probe on a flexible arm moves across the surface. A laser detects how the arm bends, giving a 3D map of the surface at near-atomic resolution. Specimens do not need a vacuum, so living material can be studied.
  • Super-resolved fluorescence microscopy: combines many images of individual fluorescent molecules switched on and off, beating the usual 200 nm limit of light. It allows proteins to be tracked inside living cells.
  • You will not be asked to recall details of these, but you may be asked to evaluate a new technique from information given.

Artefacts

Preparing specimens, especially for electron microscopy, involves fixing, dehydrating, staining and cutting. These steps can create things that were not in the living cell, such as air bubbles, folds, shrinkage or tears. Early electron microscopists had to check that structures such as mesosomes were real; repeated observations using different preparation methods later showed mesosomes were artefacts.

Key fact: Scientists reduce the risk of misinterpreting artefacts by using several preparation methods and by checking whether a structure appears consistently.

Common mistakes

  • Saying an electron microscope is better "because it magnifies more". The key advantage is higher resolution.
  • Saying TEM images are 3D. TEM gives 2D sections; SEM gives 3D surface images.
  • Forgetting that electron microscopes need dead specimens in a vacuum.
  • Thinking confocal microscopes use electrons. They use laser light and fluorescence.
  • Writing that a smaller resolution figure is worse. A smaller value means finer detail.

Revision questions

Try these, then check your answers below each one.

Question 1. What is meant by resolution? (Choose from: How many times bigger the image is than the object; The shortest distance between two points that can still be seen as separate; The brightness of the image; The depth of the specimen in focus.)

Answer: The shortest distance between two points that can still be seen as separate

Explanation: Resolution is the ability to distinguish two close points as separate.

Question 2. Which microscope has the best resolution? (Choose from: Light microscope; Laser scanning confocal microscope; Scanning electron microscope; Transmission electron microscope.)

Answer: Transmission electron microscope

Explanation: TEM resolves about 0.1 to 0.5 nm, better than SEM and far better than light.

Question 3. True or false? A light microscope can be used to see individual ribosomes if the magnification is high enough.

Answer: False

Explanation: Ribosomes are below the resolution limit, so extra magnification only gives a bigger blur.

Related lessons

Continue in the full course

This lesson is section 2.3 of our free OCR A-level Biology Year 1 (AS-level) course. In the full course you get every video for this section, interactive activities, a self-marking practice quiz, a printable worksheet with a mark scheme, an end-of-chapter test and your progress saved. Go to the full OCR A-level Biology Year 1 (AS-level) course.

 

 

 

 

 

 

 

bottom of page